Atomic Absorption Spectrophotometer TRAS-601is an integrated computer data processing device whose wavelength ranges from 190 to 900nm. Spectrum bandwidth with ranges of 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm. Special devices for quick gas conversion and safety protection can be used to analyze air-acetylene and nitrogen oxide flames, extending the analytic elements to over 60. In addition, it has an LCD. It is a long-life and corrosion-resistant atomization system. The device is stable and dependable. To achieve a stable flame and low noise, the gas path system is outfitted with highly precise pressure and existing stabilizing devices.
Wavelength Range | 190 to 900 nm |
Wavelength Accuracy | £ ±0.5 nm |
Wavelength Repeatability | £ 0.3 nm (single direction) |
Spectrum Bandwidth | 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm |
Resolution | <40% |
Baseline stability | ±0.004 Abs/30 min |
Characteristic concentration of copper | £ 0.04 mg/ml/1% |
Detection limit of copper | £0.008 mg/ml |
Background calibration ability | Greater than 30 times |
RS232 | including |
Printer | optional |
Power supply | 220V 3A, 50 Hz |
Package Dimensions | 1220×770×730 mm (Main instrument) 800×400×900 mm ( Accessories ) |
Weight | 160 Kg |
Built-in computer data processing and LCD
It is stable and dependable
With functions such as integral holding, peak height and area, auto-zero adjusting, deuterium lamp background correction
Multi-linear and nonlinear curve fitting, various parameters and working curves displayed on the screen, report printing, and so on
It has an interface for externally connecting PCs
Stability, to achieve better basic line stability, a double system will automatically recompense for the source of light drift and waveform drift induced by temperature variations
Quickly, the cathode lamp does not need to be preheated for an extended period, and the sample can be analyzed immediately
It is the preferred instrument by users for conducting various types’ elements methods and fast sample analysis
Used to eliminate color differences across the entire spectrum
A round light spot from the light source is chemically converted into a long white spot that enters the slit. As a result, the light flux of the double beam is increased
Long-life and corrosion-resistant atomization system
The burner is made of a new type of titanium alloy that is anti-corrosive and has a quick thermalequilibrium
Multi-functional analysis mode. For flame absorption, emission, particle permeability in graphite furnaces, and hydride generation methods
A gas path system that is both safe and reliable
Special devices for quick gas conversion and safety protection
It analyses air-acetylene and nitrogen oxides flames, extending the analytic elements to over 60
When the device is purchased, it will come with a complete set of accessories and will be ready to use
Metal analysis was performed by determining the presence and concentration of metals in a liquid sample. It also determines the metal concentrations in the samples.